Over time pressure washer hoses can start to leak, which tend to be caused from either wear and tear to the hose or damages to the seals on the connectors. The first thing to investigate is the area of the leak and if it happens to be from a connection, suspect the seals have worn out on the connector.
Gas Pressure Washer: Why does water spray out of my pressure washer`s pressure relief valve? If the pressure washer runs for more than 5 minutes when the spray wand isn`t in use, the water in the pump often overheats, causing the thermal relief valve to open and discharge hot water onto the ground.
A pump leaking water indicates that there is something wrong such as bad water seals/packings or a broken ceramic plunger, or something minor like a leak o-ring. Any of these problems can be minor at first, but prolonged neglect can lead to bigger problems.
The original adapter can wear over time, and this causes leakage. Also, the end of the garden hose may become imperfect and this will compromise the seal. The best solution would be to upgrade to a heavy-duty brass adapter, available on our website here.
Why Is There Water Leaking from the Drain Valve? This valve will release water from the tank if the pressure is too high or the temperature is above 210ยบ F. Make sure your thermostat is not set too high.
The Thermal Relief Valve, when properly matched to your pump model, will open and either discharge water to the floor or it can be routed through a discharge hose to a drain, allowing fresh water to be safely introduced to the pump while cooling it down before damage occurs.
Coolant leaks from the water pump are common and a clear sign that it`s time to replace the pump. The coolant is stored inside the water pump using a series of gaskets and seals. Once these parts wear out, loosen, or crack, you`ll end up with radiator fluid leaking out of the front of your car toward the center.
If a water pumping is leaking it cannot efficiently move coolant around the engine. If that happens the engine will get hotter and will eventually overheat. At first the temperature gauge will hit the red, then you`ll start seeing steam from under the hood.
Usually, leaks at the top of the hose are caused by a deteriorating washer. Before using a new hose, locate the washer and make sure it`s properly inserted into the coupling. Inspect the washer when you take your hose out of storage or put it into storage each season. Check the washers on your hose accessories, too.
The majority of leaking quick-connect fitting leaks are caused by a damaged O-ring, improper installation, eroded tubing, or too much torque placed on the tubing. Quick-connect fittings have a simple but powerful design.
In most cases, the leak will be caused by a loose or punctured drain hose, a fault with the drain pump, or a worn-out tub-to-pump hose. If it is possible to run the washer without causing further damage, removing the access panel and then running the washer will allow you to observe where the leak is coming from.
Overflow Tube Leak

If you have a leak at the front of your top-loading washer, this usually means you have a clogged or tilted overflow tube. This can happen from using too much detergent or incorrectly combining laundry products. If your home has soft water, keep in mind that less detergent is needed for cleaning.

Discover Relevant Questions and Answers for Your Specific Issue

the most relevant questions and answers related to your specific issue

Couple of guys tried to help me on this, perhaps you guys could come back. I forgot to mention there is a pressure tank bladder type on the discharge side. Could the air in this tank be messing with the prime. I checked the intake. It has water in it after bleeding air from the discharge system where before it was dry before purging air. I think there is air in the system and wonder if it is coming from the pressure tank?. i open up one of the discharge valves and a lot of air comes out. Should I put a valve on the pressure tank to take it off line until I get water from the well?

Mar 12, 2010 – Could it be the check valve? I took it off and the flap appears to be working correctly. This well has been here a long time. Never given me any problems. I do have galvenized couplers on the discharge and intake sides. Old. Could these be leaking even though they show no sign of water? The discharge is able to hold 30 pounds easily overnight. I do not hear any vacuum in the intake when I take it off. Could the pipe to the well have a leak? I know I would have to insert a sleeve but I do not want to go through the hassle if I do not have to. I had put on a brand new pump from the hardware store that did the same thing so I think that would elliminate the pump as being the problem.
I disconnected it for the winter and rehooked it up. The galvanized couplers on the discharge and pump side are old but do not appear to be leakeing as I taped them well. The check valve seems to be functioning well as I took it off and the flap works correctly. The well is not pulling water. there does not appear to be a vacuum on the check vale when I losen it. could the check valve be bad? I am aware I might have to resleeve the well, but do not want to hassle with this if I do not have to. I want to eliminate everything else first. i put another brand new pump on it to see if it was that. That partiuclar pump which was the same thng did not work either.
I took the pump nose off and looked at it. The one way valve appears to be working fine. The impeller is working fine also evidenced by when I turn it on witht the discharge cap off, water shoots out. When I open one of the discharge valves and turn it on, the pressure drops to 10lbs. At this point the prime water has moved through the pipe and and the pump does not soound like it has any water in it. I pull the cap off and have to “reprime it again.” It again goes back to the pressure gauage rapidly fluctuating while pump on. I disconnect pump on intake side I hear no vacuum. The guage is on the discharge side. The seals on the pump nose do not look frayed or damaged. The pump is not leaking water in any of the joints. The pipes on discharge and well side do not appear to be leaking.

ANSWER : My friend, please boil your question down. Your title has to do with riding mowers but the leaking, bladder, impeller, air bubbles, pressure tank, check valve comments seem to be migrating toward a pump of some kind – well? spa? pool? irrigation?

Briefly, any system that involves a water source, a water moving device, water storage device and ultimate useage is subject to leaks … into the system and out of the system. If this is a well and you have air in your system, your pump may be sucking air at the well or any loose connection between the tip of the pipe and the inlet to the pump. Your bladder could have failed but from what I can get from your comments, this is not the case. On the pressure side, neither air nor water will leak in … only out.

Please recheck all connections. Make sure your check valve is installed correctly and not leaking. The check valve assists the foot valve, which may have failed.

I am more inclined to think your well may be at the end of its useful life. To prove or disprove, you could have a plumber put a vacuum gage on your pump. He or she can answer this question is about 90 seconds based on this test. Expect to pay for one hour of time, which will be less than the time you have already invested in your project.

My Honda pressure washer is leaking out of the thermal relief valve and I am looking for a part,I also do not have the manual. The model number is WGC 3030 and it is 3.0 gpm 9.0HP. The number on the thermal valve is 33120004,where can I find a part?
ANSWER : Does the thermal valve just screw into the pump head, if so what size thread is it? I have 1/4, 3/8, 1/2 in stock.

I have a pressure booster pump installed which turns on automatically when we open the tap and turns off by itself when we close the tap, but when power goes and comes back(common in india), the pump will turn on even with no tap opened and does not turn off automatically and goes on running, some kind of airlock problem I think, when we just shut off and on water input several times, it again starts working well
ANSWER : Check to see if the output pipe has water in it when the pump swutches off the pump needs to be primed at all time what we normally find cases like this is the pump is higher than the supply or there is an air pocket on the output where the pressure sensor is

I have a 1/2 horse wayne shallow well pump. At times the water in the house slows to a trickel. This will happen for about 40-120 seconds then the pump seems to kick on and the pressure is restored. I have replaced the high low switch and the problem persists. Please let me know any thoughts on the problem. Thank You
ANSWER : Check air in your water tank should be less than you’re cut in pressure..

No pressure Pump reassembly. I purchased a new pump and installed it. Got machine back together and I’m not getting any pressure. What would be the signs if I don’t have the shaft key in properly? Or any other suggestions?
Water comes out of nozzle with pressure for a quick second then no pressure, just water. This is a brand new pump so was curious if I installed it wrong. Wondering before taking it apart again.
ANSWER : No pressure would be a sign that the key was not in properly.

I have a Northstar pressure washer powered by a honda GC160 engine. The last time i used it, water leaks from the bottom of the unit, whether it is running or not. When running, the pressure is fine. I have felt underneath and it appears that the water is coming from the second opening from the rear. Is there a pressure relief valve there. I have a manual but cannot find any descriptors for underneath the motor.
ANSWER : This is a piston seal issue. You can get a kit to rebuild the pump.

Oil appears to have come out of the oil filler cap. Is this a sign of overfilling the oil, or something else?
ANSWER : Id definitley say its over filled. try checking the dipstick

Honda GVC 160 lost pressure – noticed small black valve (back – rear) after pressure builds up , short spray then nothing – hot water comes shooting out the black valve – did something pop off?
ANSWER : The small black valve is called a thermal relief valve. If it is open you will have no pressure. If the water is getting hot enough to pop that valve, there might be internal problems with the pump.