Experienced gardeners share their insights in answering this question :
Many times gas tank vent gets clogged then engine will run until engine creates a huge vacuum in tank and can’t draw gas.

Loosen gas cap to Vent the tank to see if that’s the issue

How to Identify and Fix Common Gardening Problems ?

We provide a variety of viewpoints on how to identify and fix common gardening problems. Our sources include academic articles, blog posts, and personal essays from experienced gardeners :

The fuel filter might be clogged. A clogged fuel filter is most commonly caused by leaving old fuel in the leaf blower. Over time, some of the ingredients in the fuel may evaporate, leaving behind a thicker, stickier substance. This sticky fuel can clog the fuel filter and cause the engine to stall.
A faulty ignition coil will normally only fail once the engine has run long enough for the coil to become hot. If you discover that your blower is dying after it runs for a little while (basically until it gets hot), your ignition coil may be faulty and will likely need to be replaced.
Check for a dirty air filter and replace if needed.

A clogged filter limits the amount of cool air that passes over the heat exchanger, causing it to overheat and shut off. At the same time, your blower turns on to help cool it down.

Adjustment of the carburetor with the high speed screw (H) and low speed scree (L) can only be performed in the service shop. Special screwdriver 5910 890 2307 is required to make the adjustments. 1.1.1 Basic setting. . Screw both adjusting screws clockwise onto their seats.
The BGA 57 has a run time up to 25 minutes on a single charge with the AK 20 battery*, making it an ideal choice for homeowners to care for their yard, deck, sidewalks, driveway and more.
The fuel filter might be clogged. A clogged fuel filter is most commonly caused by leaving old fuel in the leaf blower. Over time, some of the ingredients in the fuel may evaporate, leaving behind a thicker, stickier substance. This sticky fuel can clog the fuel filter and cause the engine to stall.
Blower motor breakdown can be the result of anything from old age to failed bearings, high amp draw, electrical failure in the windings, dirt accumulation, and more. “The most common cause is dirt accumulation due to lack of maintenance,” said Tom Beaulieu, president of Bay Area Services Inc.
An overheating problem in the leaf blower is generally caused by a failure to vent gases or the fuel burning too hot inside the cylinder.
If your furnace shuts off after a few minutes and starts more than eight times an hour, it may require repair. Common causes of furnace short cycling include restricted airflow, a malfunctioning flame sensor, or a poorly placed thermostat.
The “Bog” simply means the engine is not receiving enough fuel when you go to wide open throttle. While there are other issues that may cause similar reactions within the carburetor, often the problem can be traced back to the accelerator pump system. Incorrect adjustment is the typical culprit.
Most STIHL gasoline-powered equipment runs on a 50:1 mixture of gasoline and 2-cycle engine oil. Knowing the proper way to mix your fuel is the first step in keeping it running strong and long.
Depending on the product, on a single charge, you can mow up to 400sqm, line trim up to 70 minutes, hedge trim up to 75 minutes, saw up to 130 cuts or leaf blow up to 100 minutes. The innovative arc shape combats overheating, and maximise run time so you can keep going for longer.
It won`t go endlessly on one charge; about 15 to 20 minutes is reasonable – if you need a blower that runs longer, get a corded or gas-powered model. And it won`t demolish that huge pile of wet leaves on your lawn – but it works well with lighter debris on hard surfaces.
Problems include dirty filters, broken wires, poor voltage supply and faulty limit switch or capacitor. You can test your limit switch with a multimeter, and clean the blower motor`s wire coils. If this doesn`t work, you may need to replace your furnace blower motor.
Like other gas-powered tools, handheld gas leaf blowers can be built using two types of engines: 2-cycle engines. 4-cycle engines.
The gas engine on your leaf blower needs to operate at a specific temperature: hot enough to burn the fuel and give the engine power but cool enough not to overheat the piston. An overheating problem in the leaf blower is generally caused by a failure to vent gases or the fuel burning too hot inside the cylinder.
To fix the problem, start by draining the gas tank.

Replace the old gas with a fresh mix of gas, being sure to add a stabilizer to keep the ethanol from gelling. Often, just getting fresh gas and stabilizer through the chainsaw`s fuel system may correct the saw and it should stay running.

Sometimes when using a back pack blower in dryer (low humidity) and dusty environment, the air movement creates static electricity that will discharge to the operator. Using the blower in high humidity will help to alleviate this shock as well.

Discover Relevant Questions and Answers for Your Specific Issue

the most relevant questions and answers related to your specific issue

Seems to start easily run for a few minutes and then slow and stop–bulb remains full –gas is good–have tried half choke in case too lean–did not solve–also seems possibly related to the angle I hold it at–seems to cut out quicker if blower tube angled more downward.
ANSWER : Your filter may be hanging up in the tank. you also my be losing compression

Read Full Q/A … : Stihl

Blower stops running after 10 to15 minutes of running
ANSWER : This could be caused by several things but the most logical is vapor lock. The unit should have a vented gas cap, try running with about 1/2 tank or so with gas cap off or just barely on, if this affects it causing it to run proper your problem is just a clogged vent in the fuel cap.

Read Full Q/A … : Stihl

Will only develop power (and run somewhat properly) when the choke is engaged about 90%. Starts fine.
ANSWER : Sounds to me as tho you may have a loose carburetor or another part that is letting air into the system. Check all bolts and screws for tightness. Also, you may need to clean the carburetor or put some cleaner in your gas. Not too much, only about a tablespoon, but check the screws/bolts first.

Read Full Q/A … : Stihl

Want run unless choke remains on – Stihl Bg72 Leaf Blower Intake
ANSWER : Probably fuel starvation.Wrong fuel air mix settings on the carb. Damaged carb diaphragm.

Read Full Q/A … : Stihl

The blower was running then sounded that it was stopping. Turn it off and know it will not allow me to pull the cord to start, feel like its lock up? How or what should I do to fix?
ANSWER : Ok.. Your fuel mix is wrong. You may save it by putting WD-40 or some kind of lubricant in the spark plug hole and try to turn with hand back and forth until you have freed it.. Works almost 85% of the time. You must get to the flywheel to try to turn, it will be located under the pull rope assembly. Good Luck… oh, dont forget to mix proper fuel mix if it frees.

Read Full Q/A … : Stihl

Echo pb500 only runs with choke open – Echo Gas Blower 162 MPH 450 CFM Blower PB500T
ANSWER : I’m not to sure about the question. But you say it runs with the chock open. Your engine will only run with the chock open. Can you clarify?

Read Full Q/A … : Stihl

Starts runs a couple of minutes then dies – Echo Gas Blower 135 MPH390 CFM Blower PB250
ANSWER : It
sounds like you have a bad Ignition Coil (Module). This is how they act
when they start going bad. When they get warm, they quit. Some will
last up to 20 minutes before they shut down. You can sometimes find a
used one pretty cheap at a small engine shop.Jim

Read Full Q/A … : Stihl

My blower only runs with 3/4 choke even after warm up.
ANSWER : Look on the carb for 2 screws side by side. where those screws go into the carb, it will be stamped with an “H” and “L”. Open the screw that is next to the “H”, counterclockwise about 1/4 turn at a time with the engine running, that should solve it.

Read Full Q/A … : Stihl